Liebherr Commercial Freezer A12 and A13 Alarm Limit Settings

A12 and A13 are settings rather than problems: A12 is the low alarm limit and A13 the high alarm limit on the Profi controller. They define the window outside which the cabinet raises a temperature alarm, and they sit in…

What A12 / A13 Alarm Limits Means

A12 and A13 are settings rather than problems: A12 is the low alarm limit and A13 the high alarm limit on the Profi controller. They define the window outside which the cabinet raises a temperature alarm, and they sit in the alarm settings section of the menu alongside the alarm delay.

Common Causes of A12 / A13 Alarm Limits

  • The limits were adjusted for a particular product or storage program
  • Default limits that no longer match what the cabinet is being used for

🔧 One Safe Check You Can Try

Read them before changing them, because an alarm limit set too wide is the most common reason a commercial cabinet drifts warm without anyone being told. A limit set too tight produces nuisance alarms during loading, which staff then start ignoring — which is the worse outcome of the two.

⚠ Why You Shouldn't Go Further Than That

  • Alarm limits are the difference between an alarm that means something and one that everybody mutes, and setting them well takes a view of what the cabinet actually holds.
  • These settings sit next to service-only items in the same menu tree, which is a reason to know exactly where you are before pressing anything.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Commercial Freezer Repair Error Codes

Behavior Not Matching What's Described Above?

If A12 / A13 Alarm Limits is showing up earlier than expected, coming with other warning signs, or you're just not sure, book a trained technician for a proper diagnosis.

FAQ

A12 / A13 Alarm Limits FAQ

Check the alarm limits before the buzzer. A high limit set generously wide will sit quietly through a temperature rise that should have raised the roof. The alarm test settles the buzzer question separately.

That depends on the product and on your own food-safety procedures rather than on a universal number. The useful principle is tight enough to catch a real excursion, wide enough that normal loading does not trip it.